Chengdu Laoken Technology Co., Ltd



 
Products

Multi-functional Dynamic Laminar Disinfecting Apparatus

Inquire now

Multi-functional Dynamic Laminar Disinfecting Apparatus

Click to enlarge image


(1) Brief Introduction
Thus it can be seen from the pollution avenues that people us are an important source of pollution. Article is one of the main media which affects air purifying (80% of the dust come from human beings). So we should adopt strict and scientific management policy to control the pollution
In order to ensure the disinfecting efficiency and great efficiency after long-term? usage, the practical use of dynamic disinfecting must adopt multi-technique and reasonable settings. Only coordinate well can achieve a perfect result because single function of disinfecting has a weakness
(2). operating principles
■ High-strength ultraviolet sterilizing
As early as 1942, scientists found that the lethal dose for ultraviolet to some microorganism is:
Staphylococcus aureus: 2180-4950uw.s/cm2
Typhoid bacillus: 2140uw.s/cm2
Bacterium coli: 2100-6400 uw.s/cm2
Bacterium aeruginosum: 6500uw.s/cm2
From 1987 to 1990, some home and abroad scientists proved that the average ultraviolet strength of 9400uw/cm2 could kill the germs in flowing air in 0.0625 to1 second. So we erect high-strength and long service life ultraviolet tube without ozone and the equipment which could improve the ultraviolet radiant intensity in the machine. So the built-in radiant intensity comes over 11000-15000uw/cm2.
The government prescribed that the ozone concentration must be less than 0.16mg/m3 in the place with creatures. So our products have been tested by SCCDC and the ozone density is less than 0.06mg/m3 in the process of working which is identical with the concentration of air.
■ Filtering, dusting and degerming
Air filtering is the most effective, safety, practical and convenient means of disinfecting. So adopting suitable filter will ensure blowing ?n airstreams attaining the required density of dust and germs. (Equal to the three-level filtering of 1st class environment requirement of china. The notebook of America for the engineers institute on heating, refrigeration and air conditioner and of 1998 pointed out)
■ Oxygen anion generator
Oxygen anion is the air microorganism for the living room of human beings. People are energetic and feel well physically in the environment with high content of oxygen anion. So our company developed high-efficiency oxygen anion generator. It can disinfect as well as produce a crisp air environment for the medical professionals.
■ Activated carbon filtering film
Activated carbon is the best remover of smog, peculiar smell, carbon monoxide, ammonia and some harmful gas. It has the features of good filtering efficiency, duplication of using and long service life.
■ High-tension electrostatic absorption
It adopts high-tension electric ion adsorbing principle to remove dust and germs. But it is difficult to attain the multi-target for the purifier. It couldn? be used as terminal purifying setup in clean operating room and also it could not be set up directly in clean room because it has lower and unstable efficiency of dusting as well as produce secondary dust. Therefore, we used it as auxiliary facility.
(3) Function and setup
1. Initial and medium effect of filtering, dustingand sterilizing
2. Ultra- strength ultraviolet
3. Standby ultraviolet tube automatic starting device
4. Mighty activated carbon deodorizing film
5. Oxygen anion to purify the air
6. Meeting trouble, Ultraviolet tube will alarm automatically
7. Meeting trouble, the fan will alarm automatically
8. Reticular cover of Stainless steel to filter once for all
9. Starting device to survey the source of pollution automatically
10. Automatically checkout equipment to examine the intensity of ultraviolet
11. Automatically defending alarm after long time
12. Optical catalyst to disinfect
13. Filtering net to alarm automatically on time
(4) Application scope
Hospitals: Operating room, maternity ward, infant room, premature infants room, germ-free area of supplying room, burn ward and serious illness nursing ward, etc.
Pharmaceutical factories: germ-free room and laboratory, etc.
Food and drink factories: manufacture workshop, packing workshop and germ-free workshop, etc.
Public places: conference room, hotels, amusement place and office, etc.
(5) Primary Aptitude Parameters:

Specifications

Items KJSJ-Y120 KDSJ-B80

Volume of application sanitary place 60 80 100 120 150 60 80 100
general place 100 120 200 250 250 100 120 150
Disinfecting blowing rate in circles ≥480 ≥640 ≥800 ≥960 ≥1200 ≥480 ≥640 ≥800
Built-in radiant intensity of ultraviolet ≥10000 ≥10000 ≥10000 ≥10000 ≥10000 ≥10000 ≥10000 ≥10000
Built-out ultraviolet leakage ≤1 ≤1 ≤1 ≤1 ≤1 ≤1 ≤1 ≤1
The ozone quantity in air while disinfecting ≤0.1 ≤0.1 ≤0.1 ≤0.1 ≤0.1 ≤0.1 ≤0.1 ≤0.1
Input power ≤190 ≤200 ≤220 ≤250 ≤380 ≤120 ≤150 ≤175
Total quantity of germs ≤20 ≤20 ≤20 ≤20 ≤20 ≤20 ≤20 ≤20
Quantity of anion 6?06 6?06 6?06 6?06 6?06 ≥6?06 ≥6?06 ≥6?06
Noise: ≤55db(A) Safety and protection categories: I class B model equipment Power supply:~220V±10% 50HZ

(6)Advanced Technology
■ Failure automatic detection alarm prompt of filtering system, etc.
Long-term and repeat use of filtering system will result in filter gauze blinding that affects the sterilization greatly. Such blinding will decrease the indoor air circulation frequency and repeat cleaning will cause that it no longer possesses the function of filtering, degerming, dusting and refreshing air, etc. However, it is impossible to check the filtering system daily in service use and thus automatic detection function could lighten the working load, strengthen the management and make the sterilizer normally operating at all hours.
■ High-strength ultraviolet intensity detecting
Only the built-in ultraviolet strength attains over 600 uw/m2, can it achieve greatest disinfecting effect. So you can examine the ultraviolet strength in the machine at any time, It is not only no need to use ?ltra-violet strength detector?to check it one by one but also it will do no harm to the operators who detect the built-in ultraviolet strength. It is the management to the emollient guarantee of the work environment and science
■ Standby ultraviolet tube automatic staring device
Meeting trouble of the ultraviolet tube, there? no need to replace the ultraviolet tube immediately because the standby ultraviolet tube will operate automatically which ensures the normal operation of the machine.
■ Infrared microwave automatic detection of environment pollution
The sterilizer detects working environment automatically at any time.. Once if finds a human body, the sterilizer will go into operation automatically and then will stop work automatically after the people have left for ten minutes. (if any body entered the sterilized room, it will cause secondary pollution). Therefore, to control the microorganism in air is mainly to reduce the pollution brought by people and in this way it could keep the indoor air reaching the stable sterilization effect and finally achieve the real dynamic sterilization.
(7) Performance comparison with similar products
Items\products Laoken air disinfecting machine Static absorbing machine Circle wind ultraviolet dynamic machine
National patent Available: patent No. : ZL 99231743.6 have Have not
Disinfecting function Initial-effect and middle-effect filtration; High-strength ultraviolet rays; static absorbing ;activated carbon filtration ;negative oxygen ion static absorbing ;activated carbon filtration ;negative oxygen ion Initial-effect filtration;
High-strength ultraviolet rays
Intensity of ultraviolet in disinfecting High:≥11000uw/cm2 Have not Middle
Enhancing equipment for ultraviolet radiation Have Have not Have not
Ultraviolet leakage outside of the machine ≤1um/cm2 / No results
Detecting of the ultraviolet intensity Have Have not Have not
Ozone concentration during work process Lower than the standard of the country Lower than the standard of the country No result
Physical filtering system Initial-effect and middle-effect Initial-effect Initial-effect
Function of second ?revention of contamination Have Have not Have not
Stability of sterilization (after long-term? usage) Good Better Not good
Maintenance cost Low High Low
Negative oxygen ion fresh air Have Have Have not
Time control manner Combining of any two manners among program-control, remote-control, and electronic-timing Simple and single function Simple and single function
Disinfecting time-accumulating system Have: automatic timing , over-time protecting alarm Have not Have not